POS Clock Drifts After Network Reconnect
Summary
This guide helps you troubleshoot and resolve: POS Clock Drifts After Network Reconnect. Follow the steps below to fix the issue.
Common Causes
Incorrect timestamps on shopfront Point of Sale (POS) terminals can cause significant issues with sales records, receipt printing, and payment processing. After a network drop-out or reconnection, a Windows terminal may fail to resynchronise its clock, leading to drifted times across your registers. This guide helps you isolate whether the cause is a local hardware issue, domain synchronisation failure, or an incorrect cloud time source.
Quick Fix Steps
- Restart the affected POS terminal to force an immediate time synchronisation attempt.
- Manually check the date and time in the bottom-right corner of the Windows taskbar.
- Compare the terminal time against a known accurate source, such as your mobile phone or the store's network router.
- If the time remains incorrect, proceed to the detailed instructions below.
Detailed Instructions
1. Check Windows Time Service
- Press
Windows Key + R, typeservices.msc, and press Enter. - In the Services window, locate Windows Time in the list.
- Double-click Windows Time to open its properties.
- Ensure Startup type is set to Automatic.
- If the service is stopped, click Start, then click OK.
2. Force Manual Synchronisation
- Right-click the clock in the taskbar and select Adjust date/time.
- Ensure Set time automatically is turned On.
- Click Sync now to force an immediate synchronisation.
3. Verify the Time Source
- Open Command Prompt as Administrator.
- Run the command:
w32tm /query /source - Review the output to see which server the terminal is using.
- If the source is incorrect or unreachable, run:
w32tm /resync
Troubleshooting
Isolate CMOS Battery Failure
If the terminal loses time completely when powered off or unplugged, the CMOS battery on the motherboard may be flat. This small coin-cell battery maintains the hardware clock when the PC is off. A failing battery often results in the clock resetting to a default date (such as 2009 or 2010) after a power loss.
Replace the CMOS battery or contact your IT provider to arrange a motherboard service.
Domain Controller Synchronisation
For terminals joined to a business domain, time should synchronise with the domain controller rather than a public internet server. If the domain controller's clock is drifting, all connected terminals will follow.
- Confirm the terminal is connected to the local network.
- Run
w32tm /query /statusin Command Prompt. - Check if the source references your local domain controller.
- If synchronisation fails, contact your network administrator to verify the domain controller time service.
NTP Cloud Source Issues
Standalone terminals not on a domain rely on public NTP servers. If your store's internet connection is unstable, the terminal may fail to reach these servers after a reconnection.
- Right-click the clock in the taskbar and select Adjust date/time.
- Toggle Set time automatically off, wait ten seconds, then toggle it back on.
- Click Sync now.
For further assistance with POS terminal time issues, contact your IT support provider.
Still Having Issues?
💻 Open a Ticket