Common Causes

Following a recent security update to your clinic's perimeter firewall or endpoint protection profile, SoftDent imaging hardware may fail to transmit X-rays and digital scans across the practice network. This typically occurs when the update blocks a non-standard TCP port used by legacy imaging bridges. Restoring imaging connectivity requires identifying the required port range and creating a targeted firewall exception limited to your imaging server and workstation subnet, ensuring your patient management database remains protected from broader internet exposure.

Quick Fix Steps

  1. Confirm which TCP port your SoftDent imaging bridge requires.
  2. Identify the IP address range for your imaging server and workstation subnet.
  3. Create a firewall exception allowing inbound and outbound traffic on that port between those devices only.
  4. Test image transmission from an imaging workstation to the SoftDent server.

Detailed Instructions

Identify the Required Imaging Port

  1. Open SoftDent on a workstation that can successfully connect to the imaging server.
  2. Navigate to Setup > Imaging Configuration.
  3. Record the TCP port number listed for the imaging bridge or digital capture service.
  4. If you are unsure, check the SoftDent installation documentation or contact your software vendor for the exact port used by your version.

Identify Your Imaging Subnet

  1. On the imaging server, open Command Prompt.
  2. Type ipconfig and press Enter.
  3. Note the IPv4 address and subnet mask for the network adapter connected to your clinic LAN.
  4. Calculate the subnet range (for example, 192.168.10.0/24) so the firewall rule can be restricted to your local imaging devices.

Create the Firewall Exception

  1. Log in to your perimeter firewall or endpoint security management console with administrator credentials.
  2. Navigate to the firewall rules, access control, or security policy section.
  3. Create a new inbound and outbound rule with the following settings:
    • Protocol: TCP
    • Port: The SoftDent imaging port identified earlier
    • Source: Your imaging workstation subnet
    • Destination: Your imaging server IP address
    • Action: Allow
  4. Save the rule and apply the configuration to the firewall.
  5. If you use endpoint security software on individual workstations, ensure the same port is allowed through the local firewall profile on those devices.
We recommend restricting the SoftDent imaging port strictly to your internal clinic subnet. Do not open the port to the public internet, as this helps protect patient data and maintain compliance with the Privacy Act 1988 and Australian Privacy Principles.

Verify Connectivity

  1. From an imaging workstation, launch SoftDent and attempt to capture or import a test image.
  2. Confirm the image transmits successfully to the SoftDent server without timeout errors.
  3. If transmission fails, re-check that the firewall rule applies to both inbound and outbound traffic and that no additional endpoint security profile is blocking the port.

Troubleshooting

Images Still Fail to Transmit After Firewall Rule Is Added

Cannot Access Firewall Management Console

If imaging connectivity is not restored after following these steps, Open a Ticket and our team will investigate your firewall and endpoint security configuration.

Still Having Issues?

Need more help? If the issue persists after trying these steps, please open a support ticket and our team will assist you.