Workshop PLC Serial Port Not Working After Windows 11 Update

Summary

This guide helps you troubleshoot and resolve: Workshop PLC Serial Port Not Working After Windows 11 Update. Follow the steps below to fix the issue.

Quick Tip: Need immediate assistance? 💻 Open a Ticket

Common Causes

Workshop PCs across Brisbane and the Gold Coast manufacturing centres often connect to Programmable Logic Controllers (PLCs) using serial (RS-232) ports or USB-to-serial adapters. After a Windows 11 feature update, these connections can fail because COM port assignments change, drivers become outdated, or unsigned serial drivers are blocked by Windows security. This guide helps manufacturing organisations restore communication between their workshop PC and PLC so production can resume safely.

Before changing any COM port assignments on active manufacturing equipment, confirm the production impact with the site supervisor. Changing port mappings on a live HMI or SCADA system can interrupt production and may require a controlled shutdown of connected machinery.

Quick Fix Steps

  1. Restart the workshop PC using the proper Windows shutdown procedure and check if the PLC communication resumes.
  2. Open Device Manager and look for any devices with a yellow warning triangle under Ports (COM & LPT).
  3. Document the original COM port settings before making any changes so you can roll back if needed.
  4. Confirm which COM number your manufacturing software expects and compare it to the port listed in Device Manager.
  5. If the numbers do not match, reassign the COM port to match your software configuration.
  6. Check BIOS/UEFI settings to ensure the legacy serial port is enabled.
  7. Test communication using a loopback plug before returning the machine to production.

Detailed Instructions

1. Check Device Manager for Serial Port Issues

  1. Right-click the Start button and select Device Manager.
  2. Expand the Ports (COM & LPT) section.
  3. Look for entries such as USB Serial Port, Serial Port, or the name of your USB-to-serial adapter.
  4. If you see a yellow exclamation mark or the device is listed under Other devices, the driver may be missing or blocked.
  5. Note whether the device appears as a native RS-232 port or a USB-to-serial adapter, as the troubleshooting steps differ for each.

2. Check BIOS/UEFI for Legacy Serial Port Enablement

  1. Restart the industrial PC and enter the BIOS/UEFI setup (commonly by pressing Del, F2, or F10 during boot, depending on the manufacturer).
  2. Navigate to the Advanced, Integrated Peripherals, or Onboard Devices menu.
  3. Locate the setting for the serial port (often labelled Serial Port 1, COM1, or UART).
  4. Ensure the serial port is set to Enabled and not Disabled or Auto.
  5. Save changes and exit the BIOS/UEFI, then allow Windows 11 to boot normally.
BIOS/UEFI menus vary by industrial PC manufacturer. If you are unsure which setting controls the serial port, consult the hardware documentation for your specific model.

3. Check for Blocked Unsigned Drivers

  1. In Device Manager, right-click the affected serial device and select Properties.
  2. Go to the Driver tab and note the driver provider, version, and date.
  3. Select Driver Details to view the driver files and check for a digital signature.
  4. If the driver is unsigned or from an unknown publisher, Windows 11 may have blocked it during the update.
  5. Select Update driver, then choose Browse my computer for drivers if you have the manufacturer's installation files.
  6. Otherwise, visit the adapter or industrial PC manufacturer's website to download the latest Windows 11-compatible driver.
Do not disable driver signature enforcement permanently on a production workshop PC. Only install drivers from trusted industrial hardware vendors.

4. Check Windows 11 Security Settings That May Block Serial Communication

  1. Open Settings and go to Privacy & security.
  2. Review Windows Security settings, including Device Guard and App Control policies that may prevent unsigned serial drivers from loading.
  3. If your organisation uses Microsoft Intune or Endpoint Manager, check with your IT administrator whether device control policies are blocking USB-to-serial adapters.
  4. Review Event Viewer under Windows Logs > System for serial driver errors or security blocks around the time of the Windows update.

5. Reassign the COM Port Number

  1. Document the current COM port assignment before making changes.
  2. In Device Manager, right-click the serial port and select Properties.
  3. Open the Port Settings tab and click Advanced.
  4. In the COM Port Number dropdown, select the COM number expected by your manufacturing software (commonly COM1 through COM4).
  5. Click OK to close the Advanced Settings window, then click OK again to close Properties.
  6. Restart the PC to apply the port mapping change.
If the COM number you need is already in use by another device, disable or disconnect that device first, or choose a different available COM number and update your software settings to match.

6. Update Manufacturing Software Port Settings

  1. Open your HMI or production control software, such as Wonderware, Ignition, FactoryTalk, or a similar SCADA platform used in Australian manufacturing.
  2. Navigate to the communications or connection settings menu.
  3. Verify the selected COM port matches the port assigned in Device Manager.
  4. Check the baud rate, parity, data bits, and stop bits against your PLC documentation.
  5. Save the settings and attempt to reconnect to the PLC.

7. Test Communication with a Loopback Plug

Before powering down any workshop PC, follow your organisation's proper shutdown procedure. Do not simply switch off the power at the wall, as this can corrupt Windows 11 system files and disrupt industrial control software. Only perform loopback tests during scheduled maintenance windows.
  1. Shut down the PC using the standard Windows shutdown procedure.
  2. Disconnect the PLC cable from the serial port.
  3. Insert a serial loopback plug (RS-232 loopback adapter) into the port.
  4. Power on the PC and allow Windows 11 to start fully.
  5. Open a serial terminal application such as PuTTY or the diagnostic tool provided with your manufacturing software.
  6. Select the correct COM port and send a test string.
  7. If the data is received back correctly, the port and driver are functioning.
  8. Remove the loopback plug, reconnect the PLC cable, and verify full communication with the controller.

Troubleshooting

PLC Still Not Communicating

  • Native RS-232 vs USB-to-serial: If you are using a native motherboard serial port, check BIOS/UEFI settings as described above. If you are using a USB-to-serial adapter, try a different USB port, preferably one directly on the motherboard rather than a hub.
  • Confirm the PLC is powered on and the serial cable is not damaged.
  • Check Windows Event Viewer under Windows Logs > System for serial driver errors around the time of the update.
  • If the issue started immediately after a Windows update, consider rolling back the driver in Device Manager by selecting Properties > Driver > Roll Back Driver if the option is available.
  • If the issue persists after driver updates, check whether you can roll back the Windows 11 feature update. Go to Settings > System > Recovery and look for Go back under Recovery options. This option is typically available for ten days after a feature update.

COM Port Not Listed at All

  • Disconnect the serial adapter, wait ten seconds, and reconnect it.
  • Check Device Manager > View > Show hidden devices to see if the port appears greyed out.
  • Try the adapter on another Windows 11 PC to rule out hardware failure.
  • Verify in BIOS/UEFI that the onboard serial port has not been disabled.

If you have completed these steps and the serial connection is still not working, please Open a Ticket and our team will assist with further diagnostics.

Still Having Issues?

Need more help? If the issue persists after trying these steps, please open a support ticket and our team will assist you.

💻 Open a Ticket